84 880 Technical/Service Manual
When configuration is complete, exit setup mode. Initialize the batch by turning the 3-way switch to ABORT, then
unlock the STOP button (the STOP button must be in the OUT position to allow the batch process to run). The
batching switch is now ready to use.
WARNING
If no digital input is assigned to BATRUN, batching proceeds as if BATRUN were always on: the batch will
start when the 3-way switch is turned to RUN, but the STO
P mushroom button will not function.
To begin a batch process, turn the 3-way switch to START momentarily. If the STOP button is pushed during the
batch process, the process halts and the button locks in the IN position.
The
START switch is ignored while the STOP button is locked in the IN position. The STOP button must be turned
counterclockwise to unlock it, then released into the OUT position to enable the 3-way switch.
To restart an interrupted batch from the step where it left of
f, do the following:
1. Unlock STOP button (OUT position).
2. Turn 3-way switch to
START.
To restart an interrupted batch from the first batch step, do the following:
1. Turn 3-way switch to
ABORT.
2. Unlock STOP button (OUT position).
3. Turn 3-way switch to
START.
Note
Use this procedure (or the BATRESET serial command) to initialize the new batch routine following any change