Table 3-6. Format Menu Parameters
FORMAT Menu
Parameter Choices Description
If SPLIT = OFF
PRI DECPNT
DSPDIV
UNITS
Primary Units – Settings determine the scal
e capacity and specifies the decimal point, display
division and units used. The primary units will display the lb annunciator unless secondary units
is set to lb. See Tab le 1-2 on page 4 for details.
SEC DECPNT
DSPDIV
UNITS
Secondary Units – Settings determine the Secondary
, or Alternate, units value, decimal
location, and display division size. The secondary units will display the kg annunciator unless
primary units is set to kg. See Tab le 1-2 on page 4 for details.
If SPLIT = OFF submenu
DECPNT 888888
888880
8.88888
88.8888
888.888
8888.88
88888.8
Decimal Point Location – when combined with the dec
imal point location, specifies the
location of the decimal point or dummy zeroed in the unit display.
DSPDIV 1D
2D
5D
Display Divisions – Selects the minimum division size for the displayed weight. Scale capacity
is determined by display division x graduations.
UNITS LB
KG
OZ
TN
T
G
NONE
Units – Specifies units for displayed and printed weight.
LB = pound (lights lb LED)
KG = kilogram (lights kg LED)
OZ = ounces
TN = short ton
T = metric ton
G = gram
If SPLIT = 2RNG, 3RNG, 2INTVL, or 3INTVL
DECPT1
DECPT2
DECPT3
888888
888880
8.88888
88.8888
888.888
8888.88
88888.8
Decimal Point Location – Specifies the location of
the decimal point or dummy zeroed in the
unit display.
DDIV1
DDIV2
DDIV3
1D
2D
5D
Display Divisions – when combined with the dec
imal point location, specifies the minimum
division size for the displayed weight.
MAX1
MAX2
MAX3
2000
5000
10000
Maximum weight for first range or interval.
Maximum weight for second range or interval.
Maximum weight for third range or interval.
Lights annunciators R1, R2 and R3 under the weight display.
UNITS LB
KG
OZ
TN
T
G
NONE
Units – Specifies units for displayed and printed weight.
LB = pound
KG = kilogram
OZ = ounces
TN = short ton
T = metric ton
G = gram
Configuration 35