Table 3-8. Feature Menu Parameters
FEATUR Menu
Parameter Choices Description
REGION REGULA
REGWRD
DECFMT
TIME
DATE
Selects regional settings. S
ee Level 3 sub menus.
UID 000000 Sets the unit ID, a string of up to 6 ASCII char
acters, which can be set via serial port or
keypad. This will be used in place of the <UID> token in a print format. The default value is “1.”
The Unit ID is also used as part
of the File Name for configuration storage and printing to USB
Flash Drives.
CONSC# CURVAL
RESVAL
Allows sequential numbering for pr
int operations (CURVAL is the current value and RESVAL is
the reset value). The consecutive number value is incremented following each print operation
that includes <CN> in the ticket format. When the consecutive number is reset, it is reset to
the RESVAL specified in the parameter.
PASSWD USER
SETUP
Sets a password to access the SETUP menu, or
certain sub-menus in the USER menu.
Specify a non-zero value to enable the password.
The SETUP password protects the entire SETUP menu, and when set is r
equired even
when attempting entry into the SETUP menu using the setup switch.
The USER password restricts access to the T
ime/Date, Accumulator, and Setpoints
sub-menus in the User menu.
Passwords can be overridden by loading new firmware, or entering 999999.
Note
Overriding passwords will clear configuration and calibration settings. To
preserve settings (i.e., ID information), use Revolution
software to upload
the data to a PC, then download it back to the 880 after the password
override is performed.
KEYLCK ZERO
GRSNET
UNITS
PRINT
TARE
MENU
Key Lock – Disables the listed keys. Select Lock t
o disable the key, and Unlock to enable the
key.
LOCALE OFF
ON
Gravity compensation enable/disable.
Set this parameter ON to enable the LATUDE and ELEVAT
LATUDE 45
0-90
Press ENTER to display and edit the latitude in
degrees for gravity adjustment to calibration.
(LOCALE must be set to ON)
ELEVAT 345
-9999 to +9999
Press ENTER to display and edit the e
levation in meters for gravity adjustment to calibration.
(LOCALE must be set to ON)