72 880 Technical/Service Manual
Setpoints Menu
Table 6-16. Setpoints EDP Commands
Command Menu Description Choices / Range
SP.ACCESS#n ACCESS Setpoint access in top level
menu (user) OFF, ON
SP.BANDVAL#n BNDVAL Band value 0 - 999999
SP.BRANCH#n BRANCH Branch destination 0,1-20
SP.CLRACCM#n CLRACM Clear accumulator OFF, ON
SP.CLRTAR#n CLRTAR Clear tare OFF, ON
SP.DIGOUT#n DIGOUT Lists all digital output bits available for the
specified SLOT
NONE, BIT1 – BIT4
SP.END#n END Ending setpoint number for TIMER and CONCUR 1- 20
SP.HYSTER#n HYSTER Hysteresis Range:
0 - 65535 (for the COUNTR and
DEL
AY setpoints)
0 - 999999 (for the GROSS,
NET
, and %REL setpoints)
SP.KIND#n Selection made
di
rectly after
dropping down
from SETPT x
Supported setpoint kinds OFF, GROSS, NET, -GROSS,
-NET, %REL, PAUSE, DELAY,
WAITSS, COUNTR, AUTJOG,
TIMER, CONCUR
SP.BATSEQ#n BATSEQ Specifies whether the setpoint is a batch step OFF, ON
SP.NAME#n NAME Setpoint name string Alphanumeric, Max Length: 6
SP.PCOUNT#n PCOUNT Preact learn interval (number of cycles before it
l
earns)
Range: 0 - 65535
SP.PREACT#n PREACT Preact type OFF, ON, LEARN
SP.PREADJ#n PREADJ Preact adjustment percentage Range: 0 – 999999
SP.PRESTAB#n PRESTB Preact learn stability Range: 0 - 65535
SP.PREVAL#n PREVAL Preact value Range: 0 - 999999
SP.PSHACCM#n PSHACM Push accumulate OFF, ON, ONQUIET
SP.PSHPRINT#n PSHPRT Push print OFF, ON, WAITSS
SP.PSHTARE#n PSHTAR Push tare OFF, ON
SP.RELNUM#n RELNUM Relative setpoint number 1- 20
SP.SENSE#n SENSE Digital output sense NORMAL, INVERT
SP.DSLOT#n SLOT Digital output slot NONE, SLOT0, SLOT1
SP.START#n START Starting setpoint number for
TIMER and CONCUR 1- 20
SP.TRIP#n TRIP Specifies when the setpoin
t is satisfied when
compared to value
HIGHER, LOWER, INBAND,
OUTBAND
SP.VALUE#n VALUE Setpoint value Range:
0 - 65535 (for the COUNTR
an
d DELAY setpoints)
0 - 999999 (for the GROSS,
NET
, and %REL setpoints)
BATCHNG BATCHG Batching enable OFF, AUTO, MANUAL
For setpoint commands the “n” symbolizes the setpoint number, 1-20.
Different setpoint parameters are available and accepted depending
on KIND, TRIP, and PREACT. These
restrictions are listed below by the EDP command
name but the same applies to access by menu.