Rice-lake 880 Performance Series Indicator/Controller Techni Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Balanças Rice-lake 880 Performance Series Indicator/Controller Techni. Rice Lake 880 Performance Series Indicator/Controller Technical/Service Manual User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 120
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes

Resumo do Conteúdo

Página 1 - Technical/Service

158387 Rev C880 Performance SeriesPanel Mount Controller/IndicatorVersion 1.01Technical/Service Manual

Página 2

Table 1-1. Key FunctionsKey FunctionZEROSets the current gross weight to zero.Also used to navigate to different menu levels or used to increment a nu

Página 3 - Contents

94 880 Technical/Service Manual10.0 Appendix10.1 Error MessagesThe 880 indicator provides a number of error messages. When an error occurs, the messag

Página 4

Appendix 9510.2 Using the HARDWARE CommandThe HARDWARE serial command can be used to verify that installed option cards are recognized by the system.

Página 5

96 880 Technical/Service Manual10.4 Status MessagesThe EDP command P can be used to provide status about the indicator. •The P EDP command returns wha

Página 6

Appendix 97Table 10-5 lists the sub-parameters available when configuring a scale using INDUST mode. The table includes the default values of the INDU

Página 7 - 1.0 Introduction

98 880 Technical/Service Manual10.6.3 RS-485 Data FormatsThe 880 has a built-in RS-485 software protocol which is enabled when configuring a port’s TY

Página 8 - General Safety

Appendix 99Example: To send the XG#1 command from an ASCII terminal to an indicator at address 65 (decimal) on the RS-485 network, use the format show

Página 9 - 1.3 Front Panel Display

100 880 Technical/Service ManualB12 Dynamic =00 if UNITS=PRIMARY=01 if UNITS=PRIMARY=10 if UNITS=PRIMARY=11 (note used)B13 Configuration =00 (not used

Página 10 - Standstill LED

Appendix 101<wspec [–] [0] digit[[.]digit]> Scale weight Weight for the source scale. wspec is defined as follows:wspec Indicates whether the we

Página 11 - 1.4 Indicator Operations

102 880 Technical/Service Manual10.8 Stream Formatting Examples10.8.1 Toledo 8142 IndicatorSample string for Toledo 8142 indicator (with no checksum):

Página 12 - 1.4.8 Front Panel Setup

Appendix 10310.8.2 Cardinal 738 IndicatorSample string for the Cardinal 738 indicator:<CR><POL><wwwwww><S><SP><units&

Página 13 - Turn Setpoint On or Off

PTTIntroduction 51.4 Indicator OperationsBasic 880 operations are summarized below:1.4.1 Toggle Gross/Net Mode1. Press GROSSNETB/N to toggle the displ

Página 14 - 1.4.13 Clear the Accumulator

104 880 Technical/Service Manual10.8.3 Weightronix WI 120 IndicatorSample string for the Weightronix WI120 indicator:<SP><G/N><POL>&

Página 15 - 1.4.14 Display Tare

Appendix 10510.9 ASCII Character ChartUse the decimal values for ASCII characters listed in Tables 10-10 and 10-11 when specifying print format string

Página 16 - 2.0 Installation

ASCII Dec Hex ASCII Dec Hex ASCII Dec Hex ASCII Dec HexÇ 128 80 á 160 A0 192 C0  224 E0ü 129 81 í 161 A1 193 C1  225 E1é 130 82 ó 162 A2 194 C2  22

Página 17 - 2.2 Panel Mount Installation

Appendix 10710.10 Digital FilteringDigital filtering can be used to create a stable scale reading in challenging environments. The 880 has two filteri

Página 18 - Important

108 880 Technical/Service Manual10.11 Analog Output CalibrationSee Section 3.0, Table 3-17 for ANALOG OUTPUT parameters.The following calibration proc

Página 19 - J1 J2 J3 J4 J5 J6

Appendix 10910.12 SpecificationsPowerLine Voltages Input Voltage – 100-240VAC, 9-36VDCInput Frequency – 47-63HzPower ConsumptionAC: 15 watts DC: 20 wa

Página 20

110 880 Technical/Service Manual880 Limited WarrantyRice Lake Weighing Systems (RLWS) warrants that all RLWS equipment and systems properly installed

Página 21

Appendix 111For More InformationWeb SiteFrequently Asked Questions (FAQs) at http://www.ricelake.com/faqs.aspxContact InformationHours of OperationKno

Página 22 - 2.5 Cable Connections

112 880 Technical/Service Manual

Página 24 - 2.7 Ethernet Communications

6 880 Technical/Service Manual1.4.6 Preset Tare (Keyed Tare)NoteTare mode must be set to keyed or both for the preset tare feature to function.1. With

Página 25 - 2.8 CPU Board

230 W. Coleman St. • Rice Lake, WI 54868 • USAU.S. 800-472-6703 • Canada/Mexico 800-321-6703 • International 715-234-9171 • Europe +31 (0) 88 2349171w

Página 26 - 2.10 Board Replacement

Introduction 71.4.10 SetpointsSetpoints must be enabled in the setup mode to be accessible in the user setup mode.To enter the setup mode:1. Remove th

Página 27

8 880 Technical/Service Manual8. Press MENU to return to weighing mode.NoteSome indicator configurations may not allow setpoints to be turned off thro

Página 28 - 2.12 Legal for Trade Sealing

Introduction 95. Press MENU to return to the weigh mode.NoteThe PRINT key only performs one accumulation, and only if the weight is above the accumula

Página 29 - 2.14 Battery Replacement

10 880 Technical/Service Manual2.0 InstallationThis section describes procedures for connecting load cells, digital I/O, and serial communications cab

Página 30 - 2.15 Replacement Parts

Installation 112.2 Panel Mount Installation 6.0" 5.3" 4.0" 3.0" 5.0"NoteThe controller can be mounted to the display DIN

Página 31

Panel for mounting indicator (Ref)Din Rail Mounting PlateDisplay Assembly6-32 Kep NutsEnsure gasket is seated properly on display assembly before moun

Página 32

Installation 132.2.1 Mounting the Controller Assembly RemotelyTo mount the controller assembly remotely a 6 pin connector (PN 153885) is required. See

Página 34 - 0 0 0 0 0 0

14 880 Technical/Service Manual2.3 Controller Box DisassemblyWARNINGThe 880 has no on/off switch. Before opening the unit, ensure the power cord is di

Página 35 - 3.2.1 Audit Menu

Installation 152.3.1 Remove Backplate of Controller AssemblyRemove the backplate of the controller assembly to gain access to the CPU board, power sup

Página 36 - 3.2.2 Setup Menu

16 880 Technical/Service Manual2.4 Display Board ReplacementIf the 880 display board must removed, use the following procedure:1. Disconnect power to

Página 37 -

Installation 172.5.2 Power ConnectionsPower connections to the 880 Panel Mount are shown below. • A three pin plug (PN 152334), is used to connect AC

Página 38 - SCALE Menu

18 880 Technical/Service ManualFor example, if the PC already has two physical RS-232 COM Ports, they most likely are designated COM1 and COM2. When

Página 39

Green LEDYel l ow LEDInstallation 19Figure 2-11. RJ45 Ethernet JackImportantThe Ethernet port is not intended for use on Telecom Networks Circuits tha

Página 40 - 3.2.4 FORMAT Menu

20 880 Technical/Service Manual2.9 Audit Trail and the Audit JumperThe 880 includes an audit trail feature that keeps track of the number and the last

Página 41 - FORMAT Menu

BackplatePower Supply BoardCable, Power to CPUCPU BoardScrews connecting power supply board to backplateScrews connecting CPU board to backplateInstal

Página 42 - 3.2.5 Calibration Menu

22 880 Technical/Service Manual2.11 Digital I/ODigital inputs can be set to provide many indicator functions, including all keypad functions except ME

Página 43

Installation 234. Insert the other screw into the hole for the setup switch access.Fillister Head ScrewFillister Head Screw5. Install the wire by thre

Página 44 - FEATUR Menu

Contents iContentsAbout This Manual ...

Página 45

12345679101213141516131718192011824 880 Technical/Service Manual2.15 Replacement PartsFigure 2-19. 880 Indicator Parts Illustration

Página 46

Table 2-6. Panel Mount Replacement PartsItem No. Part No. Description (Quantity) Qty151674 Display Assembly, 880 Panel Mount (Includes items 1-7) Ref1

Página 47

26 880 Technical/Service Manual3.0 ConfigurationTo configure the 880 indicator, the indicator must be placed in setup mode. The setup switch is access

Página 48

Configuration 273.1.3 User Setup MenuThe 880 indicator can be configured using a series of menus accessed through the indicator front panel when the i

Página 49

TMENUZEROPRINT GROSSNETB/NTAREUNITS28 880 Technical/Service ManualFigure 3-3. Five-Key Keypad Functions in Setup ModeFour front panel keys are used a

Página 50 - COM Menu

Configuration 293.1.4 Alphanumeric Entry ProcedureBecause of its limited keypad, the 880 will use the following scheme for alphanumeric entry.Display

Página 51

30 880 Technical/Service Manual3.2.2 Setup MenuSCALE FEATUR PORTSPFORMTSETPTS DIGIO ALGOUT VERSAUDIT TARESETPTST & D ACCUMSETUPFigure 3-7. Setup M

Página 52 - ETHERNET Menu

Configuration 313.2.3 Scale Menu100001-100000...30HZ7.5HZ15HZ60HZ120HZ240HZ480HZ960HZLIGHTMEDIUMHEAVYSETUP...SCALEGRADSOFF2RNG3RNG2INTVL3INTVLSP

Página 53 - 3.2.11 USB Host

32 880 Technical/Service ManualSCALE MenuParameter Choices DescriptionGRADS 100001-100000Graduations – specifies the number of full scale graduations

Página 54 - 3.2.12 Print Format Menu

Configuration 33TAREFN BOTHNOTAREPBTAREKEYEDTare function – Enables or disables push-button and keyed tare.BOTH – Both push-button and keyed tares are

Página 55

ii 880 Technical/Service Manual3.0 Configuration ...

Página 56

34 880 Technical/Service Manual3.2.4 FORMAT Menu...SCALE...FORMATPRI1D2D5DDSPDIVDECPNT8888888888808.8888888.8888888.8888888.8888888.8SETUP...

Página 57 - Configuration 51

Table 3-6. Format Menu Parameters FORMAT MenuParameter Choices DescriptionIf SPLIT = OFFPRI DECPNTDSPDIVUNITSPrimary Units – Settings determine the sc

Página 58 - SETPTS Menu

36 880 Technical/Service Manual3.2.5 Calibration MenuSCALE...CALIBRSETUP...Display and edittest weight valueWVAL WLINPOINT1Same as POINT

Página 59

Configuration 373.2.6 Feature MenuSee Section 7.0 for information about custom print formatting.CONFIG...SETUP...REGION000000UIDKEYLCKZEROUNLOCK

Página 60

Table 3-8. Feature Menu Parameters FEATUR MenuParameter Choices DescriptionREGION REGULAREGWRDDECFMTTIMEDATESelects regional settings. See Level 3 sub

Página 61

Configuration 393.2.7 Region MenuSETUP...TFORMT T SEP SETDFORMT D SEP SETREGIONREGULAREGWOR DECFMTTIME DATENTEPCANADAINDUSTGROSSBRUTTODOTCOMMANON

Página 62

40 880 Technical/Service ManualREGION Menu, REGULA / INDUST Sub menuParameter Choices DescriptionREGULA NTEPCANADAINDUSTNONEOIMLRegulatory mode – Spec

Página 63 - 4.0 Calibration

Configuration 41OVRBAS CALIBSCALEOverload Bases uses either the calibrated zero or the displayed scale zero for overload calculation.CALIB = Calibrate

Página 64 - 4.1 Front Panel Calibration

42 880 Technical/Service Manual3.2.8 Ports MenuSETUP...COMSWAPFLDBUSUSBCOM...PORTS...BYTEBOTHNONEDVCNETPRFBUSAddress Addressnumber numberUSBMEM

Página 65 - 4.1.2 Rezero

Configuration 433.2.9 Com MenuSETUP...COM...PORTS...TRIGGESTRINDCOMANDSTRLFTREMOTESTOP B12TERMINCRCR/LFECHOONOFFEOLDLY0-255PRNMSGOFFONBAUD12002

Página 66 - 4.5 Gravity Compensation

Contents iii7.1 Print Formatting Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 67 - Calibration

44 880 Technical/Service ManualCOM MenuParameter Choices DescriptionTRIGGE COMAND Setting Trigger to command allows opration of EDP commands and can p

Página 68 - 5.0 Using Revolution

Configuration 453.2.10 Ethernet Communications MenuSETUP...PORTS...ETHNETDHCPONOFFIPADRSxxx.xxx.xxx.xxxNETMSKxxx.xxx.xxx.xxxDFTGWYxxx.xxx.xx

Página 69 - 5.2 Configuration

Table 3-12. Ethernet Menu ParametersETHERNET MenuParameter Choices DescriptionDHCP ONOFFEnables (ON) or disables (OFF) Dynamic Host Configuration Prot

Página 70 - 5.4 Revolution Help

Configuration 473.2.11 USB HostUSBMEMLOAD SAVE?ALL ?CFG ?CAL ?...Figure 3-16. USB Host Menu StructureTable 3-13. USB HOST Menu ParametersUSB HOST M

Página 71 - 6.0 EDP Commands

48 880 Technical/Service Manual3.2.12 Print Format MenuPFORMT...SETUP...GFMTFMTCOMETH-SUSBCOMPORTformatNFMT SPFMTACCFMT HDRFMTformatUSBMEMET

Página 72 - 6.1.2 Reporting Commands

Configuration 493.2.13 Setpoints MenuSETUP...SP CFG...SETPTS...SETPT1BATCHGSETPT2-20OFFAUTOMANUALSame as SETPT1OFFGROSSNET-GROSS-NET%RELPAUSEDE

Página 73 - Format Menu

AGROSS, NET, -GROSS, -NET, %REL%RELSP OnlyIf PREACT is LEARNnumberVALUEHIGHERLOWERINBANDOUTBANTRIPIf TRIP=HIGHER orLOWERnumberHYSTEROFFONLEARNPREACTIf

Página 74 - Ports COM Menu

BPAUSE, DELAY, WAITSS, COUNTR, AUTJOGSLOTnumberVALUECLRACMOFFONCLRTAROFFONPSHPRTOFFONWAITSSPSHTAROFFONACCESSOFFONPSHACMOFFONONQUIENAME6ALPHASENSENORMA

Página 75 - Ports – Ethernet Menu

52 880 Technical/Service ManualSETPTS MenuParameter Choices DescriptionLevel 2 submenusSETPT 1–SETPT 20OFFGROSSNET–GROSS–NET%RELPAUSEDELAYWAITSSCOUNT

Página 76 - Feature Menu

Configuration 53PCOUNT 11–65535Preact learn interval. For setpoints with PREACT set to LEARN, specifies the number of batches after which the preact v

Página 77 - Keypad Lock Menu

iv 880 Technical/Service Manual

Página 78 - Setpoints Menu

54 880 Technical/Service Manual3.2.14 Digital Input MenuSETUP...BIT 1BIT 2-4...DIGIO...OFFPRINTZEROTAREUNITSCLEARDSPACCDSPTARNT/GRSCLRCNBATRUNB

Página 79

Configuration 553.2.15 Analog Output MenuThe ALGOUT menu is used only if the analog output option is installed. If the analog output option is install

Página 80 - Analog Out Menu

56 880 Technical/Service Manual3.2.16 Version MenuThe VERS menu is used to check the firmware version installed in the indicator and to set the indica

Página 81 - 6.1.5 Normal Mode Commands

Calibration 574.0 CalibrationThe 880 can be calibrated using the front panel, EDP commands, or Revolution. Calibration consists of the following steps

Página 82 - 6.1.6 ERROR Commands Output

58 880 Technical/Service Manual4.1 Front Panel Calibration 1. Put the indicator in setup mode using the setup switch on the back of the unit, see Figu

Página 83 - 7.0 Print Formatting

Calibration 594.1.1 Five-point linearizationFive-point linearization (using the WLIN parameter) provides increased scale accuracy by calibrating the i

Página 84 - 7.2 Default Print Formats

60 880 Technical/Service Manual4.2 LAST – Calibrating Zero Without Removing Test WeightsLast zero (typically platform scales) replaces the original ca

Página 85 - 7.3 Customizing Print Formats

Calibration 614.6 EDP Command CalibrationTo calibrate the indicator using EDP commands, the indicator COM, USBCOM or Ethernet port must be connected t

Página 86 - 7.3.3 Using Revolution

62 880 Technical/Service Manual5.0 Using Revolution®The Revolution utility provides functions used to support configuration, calibration, customizing

Página 87 - 8.0 Setpoints

Using Revolution® 635.2 Configuration5.2.1 New Configuration File1. Select NEW FILE on the tool bar (NEW under the file menu can also be used).2. Sele

Página 88

Introduction 1About This ManualThis manual is intended for use by service technicians responsible for installing and servicing 880 digital weight indi

Página 89 - 8.2 Batch Operations

NoteNote64 880 Technical/Service Manual3. Press and hold the SETUP switch (located under the Ethernet jack) while applying power to put the 880 into B

Página 90

EDP Commands 656.0 EDP CommandsThe 880 indicator can be controlled by a personal computer or terminal connected to the EDP commands which can simulate

Página 91 - 8.3 Batching Examples

66 880 Technical/Service Manual6.1.2 Reporting CommandsReporting commands (see Table 6-2) send specific information to the EDP port. These commands ca

Página 92 - Example 2

EDP Commands 67Scales MenuTable 6-3. Scales EDP CommandsCommand Menu Description Choices / RangeSC.ACCUM#1 ACCUM Accumulator OFF, ONSC.DFTHRH#1 DFTHRH

Página 93 - 9.0 Ethernet and USB

68 880 Technical/Service ManualCalibration MenuTable 6-5. CALIBR EDP CommandsCommand Menu Description Choices / RangeSC.WZERO#1 WZERO Perform zero cal

Página 94

Table 6-7. PORTS – Field Bus EDP Commands Command Menu Description Choices / RangeFB.BYTESWAP#1 SWAP Specify byte swap for FB card NONE, BYTE, BOTHFB.

Página 95 - Ethernet and USB 89

70 880 Technical/Service ManualPorts – USBCOM Menu Table 6-9. PORTS – USBCOM EDP Commands Command Menu Description Choices / RangeEDP.ECHO#2 ECHO Spec

Página 96 - with Ethernet

EDP Commands 71Regulatory Menu Table 6-12. Regulatory EDP CommandsCommand Menu Description Choices / RangeREGWORD REGWRD Term printed when weighing in

Página 97 - 9.2 USB Host

72 880 Technical/Service ManualSetpoints MenuNoteTable 6-16. Setpoints EDP Commands Command Menu Description Choices / RangeSP.ACCESS#n ACCESS Setpoin

Página 98 - Loading Configuration

GROSS, NET, -GROSS, -NET, and %REL type setpointsSP.KIND#n=GROSS, NET, -GROSS, -NET, or %RELSP.ACCESS#nSP.BNDVAL#n (if TRIP INBAND or OUTBAND only

Página 99

2 880 Technical/Service Manual1.1 Safe t ySafety Symbol DefinitionsWARNINGWARNINGImportantCAUTIONWARNINGIndicates a potentially hazardous situation th

Página 100 - 10.0 Appendix

74 880 Technical/Service ManualPrint Format MenuThe Menu items (except for HDRFMT) are listed by the format and the sub-parameters.Table 6-17. Print F

Página 101 - 10.3 ERROR Commands Output

EDP Commands 756.1.5 Normal Mode CommandsThe normal mode commands (see Table 6-20) transmit data to the EDP port on demand. The SX, EX, and all the &q

Página 102 - 10.4 Status Messages

Note76 880 Technical/Service ManualDigital I/O Control MenuTable 6-21. Digital I/O Control EDP CommandsCommand FunctionDON.b#s Set digital output on (

Página 103 - 10.6 Data Formats

Print Formatting 777.0 Print FormattingThe 880 provides five print formats. Formats GFMT and NFMT will be printed based on the current mode of operati

Página 104 - <STX>

78 880 Technical/Service Manual7.2 Default Print FormatsTable 7-2 shows the default print formats for the 880 and lists the conditions under which eac

Página 105 - ONTROL-B>AXG#1<CR>

Print Formatting 797.3 Customizing Print FormatsThe following sections describe procedures for customizing print formats using the EDP commands, the f

Página 106

80 880 Technical/Service Manual7.3.3 Using Revolution®The Revolution configuration utility provides a print formatting grid with a tool bar. The grid

Página 107

Setpoints 818.0 SetpointsThe 880 indicator provides 20 configurable setpoints for control of both indicator and external equipment functions. Setpoint

Página 108 - 10.8.1 Toledo 8142 Indicator

82 880 Technical/Service ManualWAITSS Wait for standstill. Suspends the batch sequence until the scale is at standstill. XCOUNTR Specifies the number

Página 109 - 10.8.2 Cardinal 738 Indicator

Setpoints 838.2 Batch OperationsBatches are controlled by digital inputs or EDP commands.Batch Run (BATRUN digital input) If a BATRUN digital input is

Página 110

Introduction 31.2 Operating ModesThe 880 has three modes of operation:Normal ModeNormal mode is the weighing mode of the indicator. The indicator disp

Página 111 - 10.9 ASCII Character Chart

84 880 Technical/Service ManualWhen configuration is complete, exit setup mode. Initialize the batch by turning the 3-way switch to ABORT, then unlock

Página 112

NoteSetpoints 858.3 Batching ExamplesDIGIO, SLOT 0, BIT 1 = BATSTRDIGIO, SLOT 0, BIT 2, 3 and 4 = OUTPUTExample 1The following example is used to dis

Página 113 - 10.10 Digital Filtering

86 880 Technical/Service ManualExample 2The following example uses a CONCUR setpoint to provide a two-speed simultaneous fill of a hopper to a net wei

Página 114 - (Section 4.0)

Ethernet and USB 879.0 Ethernet and USB9.1 Ethernet Server/Client ConnectionsThe 880 supports two simultaneous TCP connections, one as a server and th

Página 115 - 10.12 Specifications

88 880 Technical/Service Manual9.1.2 PC Connection to the 880 Ethernet Server Through a Network Switch or Router (Infrastructure)NoteIn some cases, de

Página 116 - 880 Limited Warranty

Ethernet and USB 89• When set to a higher value, the connection will be terminated after inactivity for the specified period of time, in seconds. The

Página 117 - For More Information

Note90 880 Technical/Service ManualUsing Revolution® with Ethernet1. Use one of the methods shown in Section 9.1.1 or 9.1.2 to connect the 880 to the

Página 118

Ethernet and USB 919.2 USB Host9.2.1 Using a USB KeyboardA USB keyboard will be detectable after plugging it in, no configuration will be required.Tab

Página 119

92 880 Technical/Service Manual• Key pressed and key released are supported for use by an iRite handler.• When a USB keyboard is connected - Indicator

Página 120 - PN 158387 Rev C

Ethernet and USB 939. Press TAR E to load the selected configuration. The display will say BUSY. When load is complete, LOADED will be displayed momen

Comentários a estes Manuais