Vista de página 0
155605
Bench Scale
CW-90B/90XB
Installation & Service
Manual
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1 - Installation & Service

155605Bench ScaleCW-90B/90XBInstallation & Service Manual

Página 2

6 CW90B/90XB Bench Scale Installation Manual4.0 TroubleshootingTable 4-1. Troubleshooting GuideSymptom Probable Cause RemedyNo display Power disconne

Página 3 - Contents

Load Cell Replacement 75.0 Load Cell ReplacementRemoving a Load Cell1. Unplug AC power from the indicator and disconnect the load cell cable from the

Página 4

8 CW90B/90XB Bench Scale Installation Manual7. Turn the scale over and back off the overload protection screw one complete turn to provide clearance.8

Página 5 - 1.0 Introduction

Replacement Parts 96.0 Replacement Parts 112114326931310151211875Figure 6-1. CW-90B/90XB Bench Scale Assembly Parts IllustrationItem No. Description Q

Página 6 - General Safety

10 CW90B/90XB Bench Scale Installation ManualCW-90B/90XB Bench Scale Limited WarrantyRice Lake Weighing Systems (RLWS) warrants that all RLWS equipmen

Página 8 - 2.4 Grounding the Scale Base

230 W. Coleman St. • Rice Lake, WI 54868 • USAU.S. 800-472-6703 • Canada/Mexico 800-321-6703 • International 715-234-9171 • Europe +31 (0)26 472 1319w

Página 10 - 4.0 Troubleshooting

iTechnical training seminars are available through Rice Lake Weighing Systems. Course descriptions and dates can be viewed at www.ricelake.com/trainin

Página 11 - 5.0 Load Cell Replacement

ii CW90B/90XB Bench Scale Installation ManualRice Lake continually offers web-based video training on a growing selection of product-related topics at

Página 12 - Installing a Load Cell

Introduction 11.0 Introduction This manual provides reference information to install and wire the CW-90B/90XB bench scale which is shown in Figure 1-1

Página 13 - 6.0 Replacement Parts

2 CW90B/90XB Bench Scale Installation Manual1.2 Safe t ySafety Symbol Definitions:W ARNINGImportantW ARNINGIndicates a potentially hazardous situation

Página 14

Installation 32.0 InstallationThe following sections explain the installation procedure for the CW-90B and CW-90XB bench scales.2.1 Unpacking Your Sca

Página 15

4 CW90B/90XB Bench Scale Installation Manual2.3 Connecting the Load Cell CableThe CW-90B and CW-90XB come with a standard 10 foot or 34 inch color-cod

Página 16

Calibration 53.0 CalibrationNote See your indicator manual for specific indicator calibration procedures.It is recommended that the scale be “exercise